BEGIN:VCALENDAR
VERSION:2.0
METHOD:PUBLISH
CALSCALE:GREGORIAN
PRODID:-//WordPress - MECv6.5.0//EN
X-ORIGINAL-URL:https://gisi-vecchio.spaziodemo.org/
X-WR-CALNAME:Gisi
X-WR-CALDESC:
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-PUBLISHED-TTL:PT1H
X-MS-OLK-FORCEINSPECTOROPEN:TRUE
BEGIN:VEVENT
CLASS:PUBLIC
DTSTART;TZID=UTC:20230922T140000
DTEND;TZID=UTC:20230922T150000
DTSTAMP:20230510T070900
UID:MEC-876bd8a49af1c7633e997e95654588d9@gisi-vecchio.spaziodemo.org
CREATED:20230510
LAST-MODIFIED:20230510
PRIORITY:5
TRANSP:OPAQUE
SUMMARY:ANIPLA TECHTALK – SRS, HOW TO DEFINE A SAFETY LOOP
DESCRIPTION:Analysing According to the IEC 61511 standard, a Safety Instrumented Function (SIF) description should contain some of the following key elements:\n1. Identification of the hazardous event: This element should identify the potential hazardous event that the SIF is designed to prevent or mitigate. This could include events such as fires, explosions, or toxic releases.\n2. Description of the intended SIF operation: This element should describe how the SIF is intended to operate to prevent or mitigate the hazardous event. This could include actions such as closing valves, sounding alarms, or initiating emergency shutdowns.\n3. Performance requirements: This element should define the required safety integrity level (SIL) for the SIF, as well as any reliability and availability requirements.\n4. Safety requirements: This element should specify the safety measures and devices that will be used to achieve the required SIL, as well as any testing and maintenance requirements.\n5. Design and implementation requirements: This element should describe the design and implementation requirements for the SIF, including the specific sensors, logic solver, and final elements that will be used, as well as any software or hardware requirements.\n6. Specify the verification and validation requirements for the safety loop, such as testing procedures and documentation requirements.\nBy including these elements in the SIF description, organizations can ensure that the SIF is designed, implemented, and tested in accordance with the requirements of the IEC 61511 standard. This approach helps to ensure the safety of the process and personnel, and can also help to minimize the risk of equipment damage and downtime.\nThe webinar will be given in English.\nISCRIVITI GRATUITAMENTE CLICCANDO QUI\n\n
URL:https://gisi-vecchio.spaziodemo.org/eventi/anipla-techtalk-srs-how-to-define-a-safety-loop/
ORGANIZER;CN=ANIPLA:MAILTO:anipla@anipla.it
CATEGORIES:Eventi patrocinati,Webinar
ATTACH;FMTTYPE=image/png:https://gisi-vecchio.spaziodemo.org/wp-content/uploads/Anipla-per-web-3.png
END:VEVENT